Aan het licht gekomen tijdens testen voor aankomende Touchstone update (KT-331).
https://touchstone.aegis.net/touchstone/scriptexecution?exec=202211180834014877342276&qn=/FHIRSandbox/Nictiz/dev/FHIR3-0-2-MM202001-Test/GenPractData-2-0/XIS-Server/medmij-gpdata-xis-1-1-serve-composition-xml#WAITING_OPER
De extensie http://nictiz.nl/fhir/StructureDefinition/code-icpc-1-nl binnen het gp-EncounterReport profiel (https://simplifier.net/packages/nictiz.fhir.nl.stu3.zib2017/2.2.6/files/765686 ) heeft geen Binding (en dus geen CodeSystem wat 'vaststaat'), maar in de kwalificatie wordt hier als system 'http://hl7.org/fhir/sid/icpc-1-nl ' gebruikt. Touchstone klaagt echter dat dit CodeSystem onbekend is. Het zit inderdaad niet in ons package en blijbkaar ook niet in FHIR core.
Opvallend is dat de uri wel gedefinieerd staat op https://www.hl7.org/fhir/stu3/terminologies-systems.html dus ergens zou ik verwachten dat het CodeSystem dan ook in core zit.